MIL-T-47303A (MI)
permanently labeled for ease of identification and shall have been
produced with the equipment and procedures that will be used for
the production of all test sets designated in the contract or
Prior to submission, the contractor shall inspect
purchase order.
the samples to the degree necessary to assure that they conform to
the requirements, including statements of findings and certificates
of conformance for materials and tests A and B of table I. A
sample containing known defects shall not be submitted unless
specifically authorized by the contracting officer (see 6.2d).
Quality conformance
4.5 Quality conformance inspection.
inspection consists of those examinations and tests specified in
4.6.1 and 4.6.2, to be conducted on MK IV electrical test sets, and
submitted for acceptance under the contract or purchase order.
Acceptance test sets shall be on an inspection lot basis (4.5.1).
Each month's production shall be
Inspection lots.
4.5.1
considered a lot for acceptance purposes.
Test sets shall be selected for sampling
Sampling.
4.5.1.1
in accordance with table 11.
Sampling plan for quality conformance tests.
TABLE II.
Sample Size
Lot Size
100%
2 to
5
5
6 to
50
7
51 to
90
11
150
91 to
13
280
151 to
16
281 to
500
19
501 to
1200
23
1201 to
3200
29
10,000
3201 to
35
10,001 to
35,000
40
35,001 and
over
In all cases:
Acceptance number is ZERO
Rejection number is ONE
When a lot is
4.5.1.2
Resubmission of rejected lots.
rejected, the contractor, at the discretion of the procuring
activity, may have the opportunity of reworking and resubmitting
The procuring activity shall determine
the entire affected lot.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.